Secure data transfer to our iCare CLINIC software at Irvine Eye Physicians and Surgeons Inc. This rich information can then be used to customize treatment plans and to measure the effect of certain interventions. Conclusion: Icare Home tonometry tends to slightly underestimate intraocular pressure. Seventy-three out of 93 (78.5) felt that self-tonometry was easy to use and 75 patients (80.6) responded that they would use the device at home. This device allows measurements throughout the day and night providing a comprehensive picture of IOP trends that might reveal spikes and/or variations not possible with measurements only taken during clinic office hours. In 65 out of 96 subjects (67.7), Icare Home results were within 2 mmHg of the Goldmann applanation tonometer. The ease of use, accuracy and reliability of the iCare HOME tonometer provides rich individual patient IOP trends and insights. The iCare Home tonometer does not require the use of anesthetic drops or air to measure the IOP.
Icare home tonometer portable#
Measurement results from the portable iCare HOME device are uploaded into a secure cloud platform and are accessible to Dr. Patients can measure their own IOP during the day. WARNING The tonometer should only be opened by qualified service personnel.
Do not push the tonometer into the eye (the tip of the probe should be 4-8mm, or 1/6 1/3 inch, from the eye).
iCare HOME provides an extensive an accurate view of the patient's diurnal or daytime IOPs. The tonometer must not come into contact with the patient’s eyes, except for the probes, which may do so for a fraction of a second during measurement. The iCare HOME Tonometer is the first device available to patients for measuring intraocular pressure (IOP) at home. Further research is needed to evaluate the performance of rebound tonometry in populations with higher IOP and assess the reliability of this technique in the early detection and follow up of glaucomatous patients.Irvine Eye Physicians and Surgeons Inc can now measure your intraocular pressure at home! The new concept with continuous monitoring provides more. Icare® HOME enables IOP monitoring anywhere and anytime, and it is one of the first methods for 24h IOP monitoring outside the clinic. Clinicians should be aware of the systematic overestimation of IOP with the ICare. Icare® HOME tonometer is designed for home use for Glaucoma Patients or suspects, who need regular IOP monitoring by Ophthalmologists recommendation.
The 95% LoA between Perkins tonometry and ICare tonometry were between -7.81 and +1.12 and between Perkins tonometry and Tono-Pen XL tonometry between -7.74 and +2.18.Ĭompared with Perkins tonometry, the ICare tonometer allows clinicians to estimate IOP with a portable, rapid, and noninvasive method with similar reliability to that offered by Tono-Pen XL. The mean of the difference between Perkins and ICare and Perkins and Tono-Pen XL was (mean +/- standard deviation) -3.35 +/- 2.28 mm Hg and -2.78 +/- 2.53 mm Hg, respectively. ICare and Tono-Pen XL significantly overestimate IOP when compared with Perkins applanation tonometry. iCare HOME2 Self-Tonometer Intraocular pressure measurement taken by this device at home is not a substitute for measurements obtained within an eye care. Icare HOME enables IOP monitoring anywhere and anytime, and it is one of the first methods for 24h IOP monitoring outside the clinic. The hypothesis of zero bias was examined by a paired t test and the 95% limits of agreement (LoA) were calculated. Icare HOME tonometer is designed for home use for Glaucoma Patients or suspects, who need regular IOP monitoring by Ophthalmologists recommendation. Tonometers were also compared by plotting the difference between the methods against the mean. Regression analysis was used to evaluate the relationship between the Perkins tonometer and the remaining tonometers used in this study. ICare tonometry was performed first, followed by Perkins applanation tonometry and Tono-Pen XL in a random order. Those with glaucoma can measure IOP themselves at different times of the day during several days as. It helps improve glaucoma management and provide peace of mind for patients. Sixty-five young subjects were assessed with each of the tonometers. iCare HOME2 Tonometer is a comfortable and easy-to-use device for patients to measure intraocular pressure at home without anaesthesia, drops, air, or other preparation. The purpose of this study is to assess the accuracy of the ICare IOP measurements by comparing them against other portable tonometers: Perkins applanation tonometer and Tono-Pen XL digital tonometer (Medtronic Solan, Jacksonville, FL). The ICare (Tiolat Oy, Helsinki, Finland) is a new portable tonometer that measures intraocular pressure (IOP) with a new rebound method, in which a very light probe is used to make momentary contact with the cornea in slow motion.